Carlisle PA Commercial Refrigeration

K&D Factory Service Inc. provides service for commercial cooking equipment to the businesses of Carlisle, PA and the surrounding areas since 1945.

Read our reviews and find out why your neighbors consider us to be their nearby source for factory authorized parts and service and commercial equipment supplies in Carlisle, PA.

Recent Jobs and Reviews in Carlisle, PA

Job Locations and Reviews

Mark B.
Mark B. Checked in
Arrived on, 9-7-23 Greg/Chris-Checked out unit found that the unit was under brewing single and double shots. Programmed all shots and showed mgr how to program them. Checked all operation ok.
Carlisle, PA 17013
Mark B.
Mark B. Checked in
Arrived on, 08/15/2023 -Justin-Arrived on site and began to check over lower oven for gas smell. During initial ignition you could smell that gas due to unit trying to light burners. Once lit the smell dissipated to where there was no smell of gas. This is normal with a lot of convection ovens during the initial heating sequence. During other ignition attempts after unit was at temperature I could not detect any other gas smells. Unit is working as it should at this time.
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived on, 7-10-23- Randy-Investigated fryer not resetting. Found left fryer has a broken button on hi temp. reset. Spoke with the cook and he stated that hi-temp trips if set at 375 deg. Fryer is located in cafe area. I’ll order new hi temp limit switch and a thermostat control. Unit is in operation at this time. Returned on, 07/12/2023- Justin-Arrived on site and installed new hi limit and thermostat in left fryer. Verified operations and performed temperature calibration of new thermostat. All checked good at this time and unit is working as it should.
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived at location on 3/3/23 - Loud noise was coming from the left side evaporators right side fan motor. I replaced the fan motor with the ACME700 kit and put the unit back together. Unit is now quite but both fans for right side evaporator are starting to do the same thing. We will have to get two more ACME700 kits and return to replace. Unit is quiet and working properly as of now. Returned to location on 3/6/23 - Removed and replaced both evap fan motors for the right side evap. Ensured system is operating properly at this time.
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived at location on 9/23/22 - spoke to manager as to what is going on with the unit. Customer stated the unit keeps running. Checked over all switch function and found that the final rinse lever wasn’t disengaging to show cpu that rack had passed through the system. Opened doors and found a spoon stuck below the actuator. Removed and verified all operation. Showed customer where to check if this issue happens again. Recommended that they look into new dish racks as theirs are starting to get folded over and warped underneath where the dogs catch it to pull through machine.
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived at location on 7/15/22 - Installed drain pan right below the drain line. Customer had a power surge protector mounted to the back of the unit so I used an electrical cord that I had and wired the drain pan up to it and plugged it into the surge protector. Unit is now evaporating the drain water as it should.
Carlisle, PA 17013
Mark B.
Mark B. Checked in
Arrived at location on 7/8/22 - Found evaporator fans not running, also found compressor contactor pulled in but compressor not running, found correct power into contactor but not coming out. I replaced contactor and condenser unit came on. I waited for unit to start coming down to temperature, unit was at 25 degrees when I left and working properly
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived at location on 7/5/22 - Checked out unit and found that the chemical line broke off and water was coming out the fitting. Repaired rinse aide line and checked operation. Found no more leaks at this time.
Carlisle, PA 17013
Mark B.
Mark B. Checked in
Arrived at location on 4/26/22 - Checked out unit and found the one side was not working so checked amps, no amps. There was power going to it. Pulled the bottom cover down and found the one wire was burnt off so turned power off and fixed the wire and checked operation, ok. Put everything back together and checked operation, ok.
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived at location on 4/1/22 - Checked over unit and found that the 20a fuse was blown for mag circuit. Unit had an active F3 error code as well. Pulled apart and swapped out fuse. Tested all components and found that the K2 anode relay was burnt on terminals and showed a lot of signs of arcing. Replaced fuse and went to test. I wanted to confirm due to the readings I got on the capacitors which indicated they were open on the .91 microfarad side of them. Unit popped fuse and showed F3 error again. We will need to acquire parts and return to replace. I know the one part is a tough one to get but at this point the unit is down and we need it. Returned to location on 4/4/22 - Installed new parts that were ordered for unit. Swapped out and let unit heat up to temp. After warmup period I had customer run product in. Verified all operation and unit is working good at this time.
Carlisle, PA 17013
Mark B.
Mark B. Checked in
Arrived at location on 1/28/22 - Reported on Wednesday kept filling and dishes have been spotty. Found pin hole in exit side tubing from rinse aid pump to manifold. Cut tubing back and reconnected. Chemical pumped good. Could not find any issue with filling. Could have been a stuck float or debri in valve that passed through. Floats are clean at time of service. Had gotten a message from chad about drain plunger being pushed down too far. Could not duplicate. O ring in tact and seems to be holding. Could of had debri on oring as well. Told staff to keep an eye on it and let us know if issue occurs again.
Carlisle, PA 17013
Mark B.
Mark B. Checked in
Arrived at location on 11/15/21 - Installed new fan blade. Applied some epoxy to the press joint on both sides to see if this helps with the longevity of the actual fan blade. I couldn’t find any other options to swap out with when I went to united as all the other motors were a lot larger in diameter with that shaft size. Will see how this works and if it does we will need to do this when we install them in the future.
Carlisle, PA 17013
Mark B.
Mark B. Checked in
Arrived at location on 8/5/21 - Evaporator was iced up and fans not running. Located UNMARKED WALK INN FREEZER condenser on the roof and put unit into defrost, Checked heaters and time clock. Clock was moving freely and seemed to be operating properly. Unit pumped down properly and contactor is ok. Removed remaining ice build up and started unit, fans would not come on so I checked power and found bad defrost termination switch. Once replaced fans came on once evap temp was low enough. System is operating properly at this time.
Carlisle, PA 17015
Mark B.
Mark B. Checked in
Arrived at location on 6/25/21 with part. Removed old one and installed new vacuum pump and hooked back up and checked operation, ok. Tested ok and got good vacuum.
Carlisle, PA 17015
Libby D.
Libby D. Checked in
BUNN COFFEE MACHINE - 04/26/21- Joey- Found unit not brewing and overflowing. head spray head clogged with scale. descaled spray head and unit. brew several batches checked all operation all ok.
Carlisle, PA 17013
Libby D.
Libby D. Checked in
WALK IN COOLER - 04/19/21- Tom - Door hinges are worn out and need replaced, Door hinges are reach in hinges, Customer would like a quote on replacing existing hinges and a quote on actual walk in hinges and regardless of what hinge he decides on he would also like a door closer installed on top of door. 04/21/21 - Voided Invoice & Refunded credit card sale (Billed in error)
Carlisle, PA 17015
Libby D.
Libby D. Checked in
Traulsen Reach-In Freezer - 04/13/21- Dave-Found unit breaker tripped. Removed wire cover and unhooked compressor then reset breaker. Unit stayed on. Tested compressor relay and found relay faulty. Ran to supply house for replacement relay and capacitor. unit is up and running fine at this time and dropping in temp.
Carlisle, PA 17015
Service C.
Service C. Checked in
Came in and installed new gas valve and thermopile on Bakers Pride Oven, tested the unit, unit heats up okay.
Carlisle, PA 17013
Service C.
Service C. Checked in
Removed harvest assist assembly and replaced with new part. Turned on Ice machine and found numerous other issues. The water was trying to start but couldn't. Once the pump motor was freed up, The compressor would not start. Tapped on the Ice cube relay, Contactor pulled in and compressor started. The Contactor is pitted and buzzing. Any of these components could fail at any time. Spoke to the facility manager about these issue and he asked to have all the parts quoted, and also quote a new machine. Managers information is attached in file room. Any quotes should be sent to him.
Carlisle, PA 17013
Service C.
Service C. Checked in
Found Walk-In Freezer compressor not running because unit was out on its internal overload, because condenser fan motor is not working and blade came off, Motor not available until tomorrow at United Harrisburg, I disconnected compressor so evaporator fans could still run, customer is okay with waiting unit tomorrow for part. 2/28/20 Replaced condenser motor and unit came on and is getting down to temperature, Unit was at 20 degrees when I left but compressor is making a wining noise unit is working properly for now but compressor may go out at any time and if it does due to age of condenser unit the whole unit should be replaced, customer would like price on replacing condenser unit, pics of data tags attached.
Carlisle, PA 17015
Service C.
Service C. Checked in
Arrived on site and Reach-In Cooler unit was unplugged. turned unit on. 134a pressures were okay. Compressor did not kick on right away. Compressor ran and shut off when calling for it to be on. it kicked back on after 20 seconds. I could only duplicate it once. compressor running at 5.85 amps and was hot, It also is running mildly rough. I did not replace evap coil due to 134a charge being okay and other issues with the reach in. I found that the temp settings were at 32 degrees. the cabinet probe does not shut off at 32 but at 26. it has a 8 degree differential which may be freezing unit up and causing the issues with the box. recommending new temp and defrost probes. I adjusted temp to 38 degrees with 6 degree differential to keep it above freezing. follow up call to verify proper operation. 12/30/19 Customer would like quote for new unit before any more work is performed. Sent Matt pic of data tag and info. Please attach a copy of quote to Melissa.bixler@carlisleccm.com
Carlisle, PA 17013
Service C.
Service C. Checked in
Reach-In Cooler Compressor was off most likely from long high temperature alarm. Restarted and unit ran. Suction pressure was low and compressor very hot despite temperature being 70 in box. Added gas and leak checked. Unit has a very small leak in evaporator coil. We can quote evaporator coil replacement.
Carlisle, PA 17013
Service C.
Service C. Checked in
Call Out-I found a long string of paper towels wrapped around the blower wheel of Blended Ice Machine, throwing it off balance. The motor and wheel had shifted off center, so I re-centered them and screwed them in place. I removed the towels but it did damage to the motor bearings and on start up it makes a grinding noise. The exhaust fan is working for now but it should be replaced. I will get pricing and work up a quote.
Carlisle, PA 17015
Service C.
Service C. Checked in
per customer the pilot was not staying lit on the right oven side. checked the thermocouple, starting to get weak. put new thermocouple in and tested the unit. unit is cycling off and on. I had to wait 15 minutes when I got here to wait for customer since he was serving students. tested the unit, operation okay.
Carlisle, PA 17015
Service C.
Service C. Checked in
Checked Coffee Machine unit and found low water flow to tank. Checked fill valve, dispense valve and all hoses and connections. Found right side check valve between fill valve and tank stuck partially closed. Removed and tried to free check valve would not work, will need replaced. 9-6-19 Returned with part. removed old check valve from the right side and installed new check valve. checked operation of unit, okay. customer said the left side was not brewing right either. found that the brew port was blocked with lime. cleaned out port and checked operation, okay. both sides were brewing the same level. also installed customer supplied filter. checked all operation, okay.
Carlisle, PA 17015

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More