Bloomsburg PA Commercial Refrigeration

K&D Factory Service Inc. provides service for commercial cooking equipment to the businesses of Bloomsburg, PA and the surrounding areas since 1945.

 

Who provides commercial kitchen equipment repair near Bloomsburg?

Your kitchen equipment must work at peak efficiency at all times, but selecting a servicing provider may be difficult when faced with claims of dependability and the greatest services.

When looking for a provider, look for high quality. This applies to all replacement parts and other restaurant supplies. Investing in high-quality kitchen equipment is always a good investment in the long term. To avoid frequent repairs and maintenance, choose a restaurant equipment repair source that offers OEM (original equipment manufacturer) parts for the top products and brands.

Customer service is another key factor to consider before deciding who will care for your restaurant's equipment. The top restaurant equipment repair firms will understand your needs and be knowledgeable enough to guide you and assist you when anything needs to be fixed.

How do you fix a frymaster fryer near Bloomsburg?

If your Frymaster isn’t working properly it could be any number of issues happening. Here are a couple of the more common issues you may be facing. 

  1. Fryer won’t heat properly: Check the power cord first. Reconnect the power cord in case it was knocked out of the outlet. If the drain safety valve is open, ensure it is completely closed. On gas models, make sure the valve is switched all the way to the ON position. Faulty controller - This component must be examined or repaired by a qualified expert
  2. When filtering, the pump either does not start or stops: Check to see if the power cable is disconnected or if a circuit breaker has been triggered.  When the pump motor overheats, the thermal overload switch trips. Allow 20-45 minutes for the motor to cool before pushing the reset switch on the pump. To check for a blockage, close the drain valve and remove the filter pan.

 

Why does my frymaster fryer say help?

The computer readout “HELP” indicates a heating problem. This could be incredibly dangerous, as it poses the threat of fire, and you should have a professional come look at it ASAP. Turn the fryer off and call K&D Factory Service for prompt assistance.

Read our reviews and find out why your neighbors consider us to be their nearby source for factory authorized parts and service and commercial equipment supplies in Bloomsburg, PA.

Recent Jobs and Reviews in Bloomsburg, PA

Job Locations and Reviews

Mark B.
Mark B. Checked in
Commercial Kitchen Equipment Maintenance Service. Changed all filters and blower belts on rooftop units, and cleaned metal mesh filters as well. Cleaned out exhausts and pans. Cleaned all rooftop coils. Cleaned coils for the ice maker and the ice box. Cleaned coils on both food holders. Checked temps for the beer cooler and drink cooler. Both were normal. All equipment is operating normally and cleaned properly. Cleaned condensate drains to all equipment with condensate drains.
Bloomsburg, PA 17815
Mark B.
Mark B. Checked in
Arrived at location on 3/16/23 - Found the unit with bad condenser fan motor. The motor is seized up and will have to be replaced. The unit will remain off while waiting on the part to come in. Returned to location on 3/21/23 - Installed new condenser fan motor. The unit comes on and is working properly. No further repairs are needed.
Bloomsburg, PA 17815
Mark B.
Mark B. Checked in
Arrived at location on 9/24/21 - Checked over unit found err on front speed display and front belt not running. Pulled cover and found motor not running. Turned off/on the conveyors and both started to run. Watched and found bad noise from motor. Found needs motor. Will order and return. Returned to location on 9/30/21 - Removed old motor and configured new one to match. Installed new motor and programmed control to match. Tested at speed. Found all ok at this time.
Bloomsburg, PA 17815
Mark B.
Mark B. Checked in
Arrived at location on 9/24/21 - Checked over unit found err on front speed display and front belt not running. Pulled cover and found motor not running. Turned off/on the conveyors and both started to run. Watched and found bad noise from motor. Found needs motor. Will order and return. Returned to location on 9/30/21 - Removed old motor and configured new one to match. Installed new motor and programmed control to match. Tested at speed. Found all ok at this time.
Bloomsburg, PA 17815
Mark B.
Mark B. Checked in
Arrived at location on 6/7/21 - Checked over unit, found motor operating. Found bushing worn and causing undue tension on shaft causing gear to free spin will order parts and return. Returned on 6/11/21 - replaced parts listed above. found shaft worn through and causing it to still slip. will need new rear shaft. will order and return. Returned on 7/7/21 - Replaced shaft, turned on let heat and verified conveyor ran smoothly with no issues. Unit is operating correctly at this time.
Bloomsburg, PA 17815
Mark B.
Mark B. Checked in
Arrived at location on 7/6/21 Found unit with breaker off. Checked over unit found no signs of anything shorting out or burnt up. Found 7.1 ohms on element and 120v supplied. Turned unit on found unit drawing 16.7 amps and element drawing 16.2 amps. Found blower operating correctly. Let unit heat for about ten minutes. Reassembled unit and stood upright let heat again for about 15 minutes with no issues. Unit is operating correctly with correct amp draws at this time, could not replicate issue at this time.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Removed existing garbage disposal and installed new garbage disposal. Wired in new unit, checked operation and plumbing for leaks. Unit operating normally at this time .
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found both VHL Griddle pilots not lighting intermittently. Found low MV signal from thermocouple. Removed and replaced both thermocouples. Found high gas pressure, 13" wc. Could not adjust due to regulator vent being blocked. Removed and replaced regulator and set to 4"wc per data tag. Lit pilots and checked operation, unit operating normally at this time.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found Reach-In Cooler unit running but struggling to reach 35° setpoint. Checked over unit, found 75% blocked condenser coil filter. Removed and cleaned filter, reinstalled filter. Unit easily reached set point and cycled normally.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found Range unit not lit, tried to light pilots found to not light, attempted to light burners found no gas. Mechanically agitated regulator and found to send gas. Replaced regulator lit pilots and burners. Unit is operating correctly at this time.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Checked over pasta cooker unit, found running per staff request watched unit until it failed, found issue is with the flame roll lit switch being faulty. will order and return. 7/12/19 Removed failed rollout switch and replaced. Noticed door was being kept open. Spoke to manager he stated since propping door open they have not had an issue. They will close door and see if new rollout switch remedies issue. If problem reoccurs we will need to I investigate excessive heat in burner area.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
FryMaster service on Electric Fryer. Repair fryer and gas overhead unit. Manually check actuator and found not functioning properly and ignition failure. No power to AIF board. Replace bad fuse and AIF board for vats.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found Frymaster Fryer-Gas unit recipe was changed. Tried to change and it would not take. Reset computer, found no change. Reset menu and had to reset computer again. Found that worked. Had to manually change selections one by one to match right side computer per manager. Only recipe not in system is chicken chalupa. Customer will need to update menu via usb. unit working at this time. ***Warranty claim rejected -- Programming is not covered under warranty***
Bloomsburg, PA 17815
Service C.
Service C. Checked in
The maintenance guys had been working on the dishwasher unit and had somethings taken apart. I checked power and I was missing a leg, so I found a bad fuse at this disconnect. The customer had a new fuse so I installed the new fuse and everything was working but the drive motor. I made the corrections on the wiring on the new contactor and overload that were installed before I showed up. The unit is running fine at this time and the maintenance will put the other things back together that they had apart before I came.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found unit giving ignition failure. Checked unit, found bad flame sensor. Will replace Far right vat left side flame sensor. 5-17-15 Removed the left flame sensor in the car right vat and installed the new one. I checked operation and the right flame sensor was not sensing flame. I pulled it and cleaned it and checked operation. The unit is working fine at this time. **Travel Charges Billed on wo# 156194**
Bloomsburg, PA 17815
Service C.
Service C. Checked in
checked over unit, found display jumping all over.due to bad connector on display on ribbon cable. Tried to repair to test unit, after some time was unable to get the display to work good enough to get into test mode. Pulled covers and found burnt wires on top rear for heater will need wire harness and display. 10/4/17 removed failed touch screen and heater links, replaced with new. Repaired burnt wire on capacitor, energized unit, checked operation. Unit operating normally at this time.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found unit off. Checked elements, found okay. Filled and energized unit, found closed drain error. Checked drain and float switch, found okay. Traced wires and found loose connection on board. Started unit, found heating contactor not pulling in. Checked t-stat, hi-limit and relay board. Found relay board calling for heat, no power out to heat relay. will need relay board replaced. 4/25/17 replaced control, energized unit, checked operation, found okay at this time.
Bloomsburg, PA 17815
Service C.
Service C. Checked in
Found unit off and out of service. Turned on, found not lighting. Checked all connections, removed covers, found HSI not getting voltage. Will need to replace. 4-11-17 replaced module and igniter. Ran found gas leaking from Pilot tube. Got Farrell from my truck to repair line. ran unit found 119. 9 volts to fan in control compartment and fan not running. A Replaced with truck stock. Unit up and running all OK at this time QWP (expedited freight)
Bloomsburg, PA 17815
Service C.
Service C. Checked in
During calibration found over heating, got 400*F, while set at 350*F, tried to calibrate via rear of control, unable to. Unit started to heat/not heat rapidly, possible issue with adjusting potentiometer built into temp control, will need to order temp control and probe. -- Removed failed temp control, installed new. Energized, checked operation, found okay. **Travel Charges billed on WO#118020
Bloomsburg, PA 17815

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More