Careers Call Now Contact Us

Clarks Summit PA Commercial Refrigeration

K&D Factory Service Inc. provides service for commercial cooking equipment to the businesses of Clarks Summit, PA and the surrounding areas since 1945.

Read our reviews and find out why your neighbors consider us to be their nearby source for factory authorized parts and service and commercial equipment supplies in Clarks Summit, PA.

Recent Jobs and Reviews in Clarks Summit, PA

Rated 4.0 out of 5 stars based on 1 customer reviews

Job Locations and Reviews

Ashley B.
Ashley B. Checked in
Commercial Dishwasher Leak Repair. Confronted with a leaking commercial dishwasher, I conducted a meticulous inspection focused on pinpointing the source of the issue. Identifying and skillfully repairing damaged seals and valves, I ensured the seamless and safe operation of the dishwasher, a pivotal element in maintaining an efficient kitchen workflow.
Clarks Summit, PA 18411
Ashley B.
Ashley B. Checked in
Repair of Commercial Proofing Cabinet: Responding to a client struggling with a commercial proofing cabinet's uneven temperature, I identified malfunctioning humidity controls and replaced them. System connections and control adjustments were rigorously tested to ensure consistent proofing conditions.
Clarks Summit, PA 18411
Mark B.
Mark B. Checked in
Arrived on, 7-25-23- Mike. Checked and found two spoons inside the disposal. Fished them out and tested the unit for operation. The unit is up and running.
Clarks Summit, PA 18411
Mark B.
Mark B. Checked in
Hot water dispenser sputtering and steaming from the spout. Checked for tangles, kinks, and loops in faucet tubs and corrected the issue. Also checked that the water supply valve is fully open.
Clarks Summit, PA 18411
Mark B.
Mark B. Checked in
Arrived at location on 10/14/21 - Unit is smaller flat top to the right of the large one. Pilot out on the left, crew member said cord got burnt up and now not heating on left. Lit left pilot, held fine. Heated, no issues. Removed burnt up cord, power switch retaining clip is broken, regulator in back covered in oil, clogged vent and needs two thermocouples. Returned same day - Replaced left thermocouple. Tested, unit holds pilot and was heating when left.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
examined DUK Hot Well unit. thermostat stem hard to move and main flame low. found blockage in orifice. main flame good. pilot not holding. need to rework pilot because well pan is deteriorating and falling into burner pushing main flame into thermocouple causing premature wear. Will order parts and return. 12/11/20 replaced thermocouple and thermostat on left side. reworked pilot assemblies to keep thermocuple away from burner. tested. good to go
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined top pizza oven unit, found no power going to controls, checked incoming power 210 v - found internal breaker was off, turned oven on, ran temp to 450, tested good.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined Dishwasher unit, found left side door spring broken, will order 2 so customer has extra one. 3/9/20 Returned and replaced spring. Left 2nd spring with customer.
Clarks Summit, PA 18411
Review
my only problem is timine and I did tell them to come when they could only after it was started and they were not aware of the involvement
Willowbrooke - Clarks Summit, PA 18411
Response from K&D Factory Service Inc.:

Your kind words mean a lot to us. Thanks for the positive feedback.

Service C.
Service C. Checked in
Finished the installation on the ice machine and bin and installed pump. Rigged a extension cord up to it to test.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined unit and found condensate drain blocked on WALK IN COOLER. Accessed roof of unit, removed covers, blew out drain.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Removed old booster and dishwasher, put new dishwasher in placed had to reroute water lines and drain lines, also had to move table left side now drain in sink in table needs to be rerouted and customer is changing power supply to three phase instead of single phase - have to return on 9/24/10 to finish. need time for other techs. 9/25/19 returned and finished hooking up drain for waste sink and customer had new 3 phase line converted unit to 3 phase and tested unit Note: need fitting for soap, they went with old unit, unit is working
Clarks Summit, PA 18411
Service C.
Service C. Checked in
examined Combi Oven unit, found customer stated door lights blinking, then not coming on ,wall on site boat door lights working, checked cables and control board, could not duplicate customers problem. Spoke to customer, they will use and advise.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined Combo Oven unit, found anywhere from 1/2 inch to 1 inch thick lime in generator and elements completely covered on 3 combi - removed as much lime as possible by hand and delimer combi generator had to do one unit at a time due to amount of food had to be cooked. Finished delime on all 3, tested operation, tested good.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined far left unit. unit lights for a few seconds then drops out. not sensing flame. Cleaned spark assembly, unit still dropping out. Traced problem to bad ignition module, swapped module with other unit to test. Will order ignition module and return. 5/30/18 Returned, removed and replaced ignition module, tested, unit lit and heated, waited for unit to cycle. Tested good
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined microwave oven unit. Reading 999CC. Pulled RTD and took ohm reading in ice water 100.2 ohms. RTD ok. Adjusted door switches. Unit heated and cooked. 13.8 on 240
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Removed and replaced contactor, potentiometer and temp board. Incorrect probe. Used old probe to test. Unit not cycling correctly. New temp board bad. Will reorder and return. Left unit unplugged. 4-10-17 Tested and found unit's contactor chatters and stays engaged sometimes. Tested and found diode bad on board from com feed to relay to N/O contact, left two as you look down at board. Removed one side of diode. Unit is working. will obtain another so interface does not disturb the operation. Note: per Brian @ Garland, diode no longer needed, build into board. A bad will cause contactor chattering and sticking.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined unit. Found hi-limit bad on second from left well. Will order and return. 3-13-17 Removed and replaced hi limit. Tested unit, heating good.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Removed and replaced pump/motor and circuit breaker switch. Tested, filter 2 vats. Tested good. QWP (expedited freight)
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined unit. Customer stated white side door slides keep coming off door. Will order and replace. 12-21-16 Jeff/Tom -- Examined unit. Removed and replaced door slides on dishwasher. Tested good.
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Examined unit. Turned unit to cook. Could clearly hear and feel buzzing noise/vibration to gas valve. Checked for voltage at PV and MV, both good. Unit needs door switches. Fan stays on with doors open. Unit also took long to cycle. Good spark but took 2-3 times to ignite. Note: quoted additional repairs of $653.19 (wo# 125014). .
Clarks Summit, PA 18411
Service C.
Service C. Checked in
Installed lower fence and thumb screw on slicer and tested - all okay. parts were purchased through K&D on parts sale
Clarks Summit, PA 18411

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More