K&D Factory Service Inc. has been bringing OEM commercial cooking parts and service to restaurants and commercial kitchens of Exeter, PA and the surrounding areas since 1945!
Read our reviews and find out why your colleagues consider us to be their nearby commercial cooking supply company in Exeter, PA.
Recent Jobs and Reviews in Exeter, PA
Our Local Reviews by City
- Allentown, PA (2)
- Annville, PA (1)
- Bechtelsville, PA (1)
- Bedford, PA (1)
- Bedminster Township, PA (1)
- Bethlehem, PA (2)
- Bird in Hand, PA (1)
- Camp Hill, PA (1)
- Carbondale, PA (1)
- Chambersburg, PA (1)
- Clarks Summit, PA (1)
- Coal Township, PA (2)
- Coalport, PA (1)
- Columbia, PA (1)
- Dallastown, PA (1)
- Danville, PA (1)
- Denver, PA (1)
- Dillsburg, PA (1)
- Dover, PA (1)
- Dunmore, PA (2)
- Dushore, PA (1)
- East Stroudsburg, PA (2)
- Easton, PA (1)
- Ebensburg, PA (2)
- Elizabethtown, PA (1)
- Elverson, PA (1)
- Elysburg, PA (1)
- Everett, PA (1)
- Gardners, PA (1)
- Gettysburg, PA (5)
- Hagerstown, MD (1)
- Hamburg, PA (1)
- Harrisburg, PA (2)
- Hershey, PA (2)
- Honesdale, PA (1)
- Honey Brook, PA (1)
- Huntingdon, PA (1)
- Indiana, PA (1)
- Jenkins Township, PA (1)
- Lancaster, PA (7)
- Larksville, PA (1)
- Lehighton, PA (1)
- Lock Haven, PA (2)
- Mifflinburg, PA (1)
- Milton, PA (1)
- Moosic, PA (1)
- Morgantown, PA (5)
- Mount Pocono, PA (2)
- Mount Union, PA (9)
- Muncy, PA (2)
- Nesquehoning, PA (1)
- North Whitehall Township, PA (1)
- Northumberland, PA (1)
- Pittston, PA (1)
- Reading, PA (2)
- Roaring Brook Township, PA (1)
- Saint Clair, PA (1)
- Saylorsburg, PA (1)
- Scranton, PA (2)
- Selinsgrove, PA (1)
- Steelton, PA (1)
- Tunkhannock, PA (1)
- Wellsboro, PA (1)
- Wernersville, PA (1)
- White Haven, PA (1)
- Whitehall, PA (2)
- Wilkes-Barre, PA (1)
Job Locations and Reviews
Manager reports that lately, the breaker for the steam table seems to randomly trip. Checked the wires and electrical components and discovered that the wire nuts at the power cord inlet box were melted and in contact with metal, causing the breaker to trip. Made repairs and installed new porcelain wire nuts. Tested and the unit working well
Checked over Mixer unit. found wet grease on top of bowl lift gear box. investigated and found grease is breaking down and traveling upwards and coming out of top. due to over filling or breaking down. looked over parts break down and found no seal for that location. unit is operating OK at this time. **Travel Charges billed on wo# 210806**
Found leak between Oven ranges, customer not using range on left side broken union free and push range on left out of the way, removed plug from manifold in left oven and put in union and put union back onto right range - turned gas on, lit pilot, tested for leaks, were none right range is in poor condition
Examined Pizza Oven unit. found safety bad. removed and replaced safety and thermocouple. tested. pilot holding. burner lit. good to go
Replaced oven safety valve and thermocouple on back kitchen top right oven, per customers request, tested okay.
Installed new drain valve and fixed two leaks on Electric Steamer.
Found JAC Dishwasher off and filled with water. Checked elements, ohmed out, Rinse the same top and bottom, wash a little higher. Turned power on cycled unit on start filling. Shut down and drained unit. Checked water level float, found hanging up. Cleaned float and retested. Unit filled rinse heater each pulled 8 amps. Rinse came up to 185* cycled off. Wash heater cycled and pulled 13amps cycled off at 185*. Ran unit thru 7 cycles. Pressure display stuck at 100 psi. Water levels held and temps held.