K&D Factory Service has been providing factory authorized kitchen equipment parts and service to the businesses of Mifflinburg, PA and the surrounding areas since 1945!
Read our reviews and find out why your colleagues call us when they need OEM parts and equipment or refrigeration repair services in Mifflinburg, PA.
Recent Jobs and Reviews in Mifflinburg, PA
Our Local Reviews by City
- Allentown, PA (2)
- Annville, PA (1)
- Bechtelsville, PA (1)
- Bedford, PA (1)
- Bedminster Township, PA (1)
- Bethlehem, PA (2)
- Bird in Hand, PA (1)
- Camp Hill, PA (1)
- Carbondale, PA (1)
- Chambersburg, PA (1)
- Clarks Summit, PA (1)
- Coal Township, PA (2)
- Coalport, PA (1)
- Columbia, PA (1)
- Dallastown, PA (1)
- Danville, PA (1)
- Denver, PA (1)
- Dillsburg, PA (1)
- Dover, PA (1)
- Dunmore, PA (2)
- Dushore, PA (1)
- East Stroudsburg, PA (2)
- Easton, PA (1)
- Ebensburg, PA (2)
- Elizabethtown, PA (1)
- Elverson, PA (1)
- Elysburg, PA (1)
- Everett, PA (1)
- Gardners, PA (1)
- Gettysburg, PA (5)
- Hagerstown, MD (1)
- Hamburg, PA (1)
- Harrisburg, PA (2)
- Hershey, PA (2)
- Honesdale, PA (1)
- Honey Brook, PA (1)
- Huntingdon, PA (1)
- Indiana, PA (1)
- Jenkins Township, PA (1)
- Lancaster, PA (7)
- Larksville, PA (1)
- Lehighton, PA (1)
- Lock Haven, PA (2)
- Mifflinburg, PA (1)
- Milton, PA (1)
- Moosic, PA (1)
- Morgantown, PA (5)
- Mount Pocono, PA (2)
- Mount Union, PA (9)
- Muncy, PA (2)
- Nesquehoning, PA (1)
- North Whitehall Township, PA (1)
- Northumberland, PA (1)
- Pittston, PA (1)
- Reading, PA (2)
- Roaring Brook Township, PA (1)
- Saint Clair, PA (1)
- Saylorsburg, PA (1)
- Scranton, PA (2)
- Selinsgrove, PA (1)
- Steelton, PA (1)
- Tunkhannock, PA (1)
- Wellsboro, PA (1)
- Wernersville, PA (1)
- White Haven, PA (1)
- Whitehall, PA (2)
- Wilkes-Barre, PA (1)
Job Locations and Reviews
Commercial Cooking Equipment Repairs: The client's convection oven had issues with the fan motor, causing uneven cooking. I repaired the motor, ensuring consistent heat distribution and cooking performance.
Commercial Hot Water Dispenser Repair. In response to inaccurate temperature control causing issues with the hot water dispenser, I executed a precise calibration of the control. This meticulous service ensured consistent and precise water temperatures, meeting the highest standards in the kitchen.
Commercial Dough Press Repair: I addressed a commercial dough press issue by repairing its swing arm. The malfunction was affecting the precision in shaping dough. Swiftly replacing the worn-out components within the swing arm, I restored optimal functionality, ensuring the press operated efficiently and maintained the consistent production of high-quality baked goods for the client.
Commercial Appliance Repair. A business owner contacted us to report a malfunctioning ice cream machine that was causing disruptions in their dessert production. I promptly arrived and identified the issue as a worn-out motor, which was hindering the ice cream machine's performance. I efficiently replaced the faulty motor, guaranteeing uninterrupted and efficient ice cream production for the client's business operations.
Commercial Hot Water Dispenser Repair. A leaky hot water dispenser was causing inconvenience. Our repairman promptly diagnosed a worn-out gasket and replaced it, putting an end to the leakage and ensuring safe and hassle-free water dispensing.
Commercial Dishwasher Repair near Chestnut St. After the dishwasher at a commercial business failed them, they contacted us for a resolution. We reviewed options with the client, and they decided on the best and most affordable appliance for the business. We arrived at the scheduled date and removed the old dishwasher and then installed the new dishwasher into the establishment. The client was relieved to have an operable dishwasher in the business!
Arrived at location on 11/29/22 - Checked over unit. Found contactor not pulling in. Replaced with truck stock. Retested and found all ok at this time.
Arrived at location on 6/14/22 - Customer explained unit showing 909f and open flashing. Called tech support and verified thermocouple is bad. No other recommendations at this time. Customer wants part ordered. Returned to location on 6/15/22 - Removed failed left thermocouple, installed new thermocouple, ran wires to terminal block, secured wiring, closed up unit, turned on and let heat, heated up to set point of 476F, burners cycling, confirmed unit working correctly at this time.
I checked Oven unit and found flame sensor bad, gas fittings leaking, gas pressure at 55 IWC. I sealed the gas leaks and leak checked. Then I was able to adjust the gas pressure down to get the unit operational but his fuel supplier is going to come out to replace the regulator. Then adjusted the main line pressures and manifold pressure on the unit to 11 IWC. The customer will let us know if he needs anything else.
Found unit running but t-stat satisfying at 49*. Turned t-stat down, found would no longer close. Replaced with temporary t-stat, set to 35*. Will order correct part and return. 4/25/17 removed temporary temp control, installed new. Energized, checked operation, calibrated, found ok at this time.
Found unit off. Tried to fill, found shutting off too soon. As soon as probe gets hot, fill shuts off. Spoke with Jim at Jackson and there is a water level board with sensitivity control that needs to be installed. Will order and return. 2/20/17 found unit off. Removed low water level sensor and made sure it was clean. Reinstalled sensor and made sure tight seal and no contact with machine body. Filled and unit stopped at proper level. Ran unit, drained, refilled 5 times with no issues. Unit working properly at this time. ** No charge labor for 2/20 per Service Manager **No Charge travel and miles per Service Manager
Found unit off, ran found contactors not engaging. Lowered computer, found when computer calls for heat, relays are not energizing. No heat, Led on interface, Swapped computer with right vat, issue stayed with interface. Will obtain new and return to replace. Will need AM service to replace I.O. board on left vat. Also top front cover is slanted forward, needs to be removed and cleaned to fit. ** No charge labor per Service Manager for 7/13/16 Found unit off, turned power off at breaker. Replaced interface, cleaned excessive oil build up from control area, re-seated front rail, ran unit, found normal operation.