K&D Factory Service Inc. has served commercial cooking businesses in Tunkhannock, PA and the surrounding areas with factory authorized parts and service since 1945!
Read our reviews and find out why your neighbors consider us to be their nearby one-stop-shop for commercial cooking equipment and repairs in Tunkhannock, PA.
Recent Jobs and Reviews in Tunkhannock, PA
Our Local Reviews by City
- Allentown, PA (2)
- Annville, PA (1)
- Bechtelsville, PA (1)
- Bedford, PA (1)
- Bedminster Township, PA (1)
- Bethlehem, PA (2)
- Bird in Hand, PA (1)
- Camp Hill, PA (1)
- Carbondale, PA (1)
- Chambersburg, PA (1)
- Clarks Summit, PA (1)
- Coal Township, PA (2)
- Coalport, PA (1)
- Columbia, PA (1)
- Dallastown, PA (1)
- Danville, PA (1)
- Denver, PA (1)
- Dillsburg, PA (1)
- Dover, PA (1)
- Dunmore, PA (2)
- Dushore, PA (1)
- East Stroudsburg, PA (2)
- Easton, PA (1)
- Ebensburg, PA (2)
- Elizabethtown, PA (1)
- Elverson, PA (1)
- Elysburg, PA (1)
- Everett, PA (1)
- Gardners, PA (1)
- Gettysburg, PA (5)
- Hagerstown, MD (1)
- Hamburg, PA (1)
- Harrisburg, PA (2)
- Hershey, PA (2)
- Honesdale, PA (1)
- Honey Brook, PA (1)
- Huntingdon, PA (1)
- Indiana, PA (1)
- Jenkins Township, PA (1)
- Lancaster, PA (7)
- Larksville, PA (1)
- Lehighton, PA (1)
- Lock Haven, PA (2)
- Mifflinburg, PA (1)
- Milton, PA (1)
- Moosic, PA (1)
- Morgantown, PA (5)
- Mount Pocono, PA (2)
- Mount Union, PA (9)
- Muncy, PA (2)
- Nesquehoning, PA (1)
- North Whitehall Township, PA (1)
- Northumberland, PA (1)
- Pittston, PA (1)
- Reading, PA (2)
- Roaring Brook Township, PA (1)
- Saint Clair, PA (1)
- Saylorsburg, PA (1)
- Scranton, PA (2)
- Selinsgrove, PA (1)
- Steelton, PA (1)
- Tunkhannock, PA (1)
- Wellsboro, PA (1)
- Wernersville, PA (1)
- White Haven, PA (1)
- Whitehall, PA (2)
- Wilkes-Barre, PA (1)
Job Locations and Reviews
Commercial Kitchen Equipment Repair: The client's beer cooler was not maintaining consistent temperatures. After recalibrating the thermostats, the cooler now keeps beverages at the ideal storage temperature.
Commercial Kitchen Equipment Repair: The client’s commercial juice dispenser had clogged spigots, causing dispensing issues. I cleaned and cleared the spigots, ensuring smooth and controlled juice flow for their customers.
Commercial Kitchen Equipment Repair: Addressing excessive frost buildup in a reach-in freezer, I replaced the defrost heater. This repair prevents ice accumulation, optimizing freezer space and preserving stored goods.
Commercial Food Warmer Installation. A client sought to enhance its kitchen operations by adding a new commercial food warmer to their setup. Our expert installation team arrived at the establishment, fully equipped for the task. We carefully positioned the food warmer in an efficient location within the kitchen, optimizing workflow. Next, we connected it to the power supply and calibrated the temperature controls to meet the precise needs of the restaurant's menu items. Rigorous testing was followed to ensure that the food warmer maintained consistent and safe serving temperatures. With the installation completed, the restaurant was now equipped with a reliable food warmer, allowing them to keep their dishes consistently hot and ready to serve, thus satisfying their patrons with steaming, delicious meals.
Pizza oven is not cooking food evenly - the bottom of pizzas are coming out undercooked after installing a new thermostat. Found that the capillary tube bulb not in the correct place for the thermostat to register. Corrected the issue and tested to find that food is now cooking evenly.
The compressor is not running but was testing fine. Inspected the unit and found a bad component that needed to be replaced. Installed a new unit and the compressor was able to run again.
Arrived at location on 1/12/23 - Spoke with customer and they would like the left thermostat replaced on the range griddle. Shut breakers off to unit and opened control panel. Had to remove bullnose to lift griddle to gain access to thermostat. Removed old thermostat and installed new one provided by customer. Reinstalled bullnose and control panels. Powered unit on and tested griddle functions. Griddle heats and cycles as should. Okay.
Arrived at location on 7/23/21 - Upon arrival, unit was off. I plugged the unit in, took an amp draw at the compressor and I'm pulling 3amps that tells me the compressor is running. I let the unit run discharge is nice and hot, suction is cool, all fans are running. Box is currently down at 34 degrees, not to sure as to why the temp rose on them in the first place but at this moment everything is working they are good to go.
Found Food Warmer unit off, power supplied shut power off and open control box and turn power back on and tested set temp at 165 °f unit came up to temp and cycled off and back on -unit would not act up while here.
Upon arrival dishwasher was tripping breaker. Found bad connection on a contactor. A new contactor was retrieved and installed. Heaters are pulling 27 amps all is good.
Arrived on site, old unit still in place and hooked up. disconnected Bunn Coffee Machinbe unit and drained. connected new unit to power and water and performed initial start up instructions. Brewed half batch of ice coffee with nothing in funnel. operation of unit is as expected. unit is calibrated from factory, did not change calibration.
Pilot lit but lazy on Gas Fryer, 430mv from thermopile, unit lit, candles and sometimes blows pilot out, pilot nut leaks gas pressure 10" . quote for 1x HP8071604 make sure it's LP gas valve Honeywell 1x 810-2055 Pilot assembly LP 1x Robert Shaw thermopile 1x enough tubing to replace pilot tubing. Note: quoting additional repairs, closing out this work order.
Examined top oven unit set 350 let fully heat and cycle actual temp 330 calibrated cycle off 353.recovers 344 good let heat, found temp controller very erratic at times, normal then 30 degree swing, cycling on 360 off 375 then back to on 348 off 367, then dropping to 330 before recovering. Will order parts, bottom oven tested good. 1/14/19 Removed and replaced temp board and potentiometer in top left oven. tested. unit cycled on temp and at 325 and 350. Set unit to 400, unit at 425 and still heating. found contactor buzzing, contactor sticking. Removed power to unit and examined contactor. Contactor bad, will order and return. 1/16/19 Removed and replaced contactor and repaired over heated wiring, checked calibration, set 350, cycled off 349 back on 341 tested good.
We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Examined unit, found no power at terminal block for left two French plates 487vac at terminal block incoming power to range found two wires burnt up inside chase of range, cut back to good wire, repaired, tested all burners, heating, tested good. ** No charge per Service Manager, recall
Removed front and top panels. Valve on top right side was leaking by. Replaced valve and machine on right side stopped dripping. Left side has a very slow drip. May need to replace that valve as well. Will order part and return. 12-12-17 Right side leaking again. Found mineral pieces inside new valve. Opened both tanks, cleaned off water probes. Vacuumed out debris in bottom of both tanks. Cleaned rt dump valve, replaced left side valve. Filled and tested. Heating no dripping.
Completed descale on boiler in steamer. Drained, found unit draining slow. Removed drain valve and cleaned lime build up out. Tested operation. Tested good.
Examined unit. Found wiring burnt off elements. Only half elements working. Replaced burnt wiring. Filled unit, filled to correct level. Drained open boiler, cleaned probes. Let fill, fully heated. Unit cycled off, 9psi. Steamed compartments. Unit cycled correctly. Drained boiler, refilled 3-4 times. Let heat. All elements heating. Unit came up to pressure and cycled off correctly. Did not find any problem with warwick controls while testing. Customer will use and advise.
Cleveland Electric Steamer Tech - Removed and replaced hand hole plate gasket. Completed clean out on boiler. Tested, checked low water cut out and pressure switches. Tested good
Cleveland Steamer Tech - Completed descale on boiler in steamer. Tested operation, fully heated, steamed compartments. Operating pressure 5 psi. Tested good.